| Project | Parameter |
| Weight | 20 Kg±0.1Kg |
| Impact Needle Diameter | Not less than 20mm |
| Force Measurement Accuracy | Not less than 0.5% |
| Anvil hardness | Surface hardness is not less than HRC 60 |
| Guide Post | The frictional resistance between the heavy object and the guide post is less than the quality requirement of the heavy object, and can meet the guiding requirement |
| Force measuring steering speed | No more than 0.3 milliseconds |
| Distance between impact pin and anvil | 1mm |
| Force plate size | Diameter 70 mm, bottom spherical radius 500mm The minimum distance between the center of the force plate and the supporting foot of the machine should not be less than 200mm |
| Flexible range | 300~400N/mm (If the elastic range exceeds the standard, a correction coefficient should be added) |
| Deformation measurement accuracy | Not less than 0.01mm |
| Measuring deformation and turning speed | No more than 0.3 milliseconds |
| Power supply | 220V ±10%, 50Hz |